| Product Name | Sodium Fluoride + EDTA K2 Tubes |
| Tube Material | PET/Glass |
| OEM/ODM | Yes |
| Certificate | CE, ISO13485, ISO9001 |
| Usage | Blood Collection |
| Sterile | Irradiation Sterilization |
| Sample | Free |
| Service | The groups we serve: are distributors, import traders, government procurement, Buying Agents, and medical chain stores. We provide one-stop procurement for you to simplify your procurement process |
The 2ml Sodium Fluoride + EDTA K2 Blood Collection Tube is a sterile, evacuated blood collection tube designed specifically for tests that require stable glucose and metabolic analyte levels. By combining sodium fluoride with EDTA K2, this tube effectively prevents blood coagulation while inhibiting glycolysis, ensuring that glucose concentration remains as close as possible to in vivo levels from the moment of collection.
This tube is widely used in hospitals, diagnostic laboratories, and health screening centers for glucose-related assays. Its precise 2 ml draw volume, standardized gray cap, and reliable vacuum system make it a dependable choice for routine and high-throughput clinical testing. For laboratories reviewing glucose tube options, technical specifications and supply support are available through EDTA TUBE.
A Sodium Fluoride + EDTA K2 blood collection tube is a vacuum blood tube containing two functional additives:
Sodium Fluoride (NaF): Acts as a glycolysis inhibitor by suppressing enzymatic activity in red blood cells, helping preserve glucose levels after blood collection.
EDTA K2: Functions as an anticoagulant by binding calcium ions, preventing clot formation, and maintaining whole blood integrity.
This dual-additive formulation is especially important in glucose testing, where post-collection metabolism can lead to falsely low results if glycolysis is not effectively inhibited. The 2 ml tube volume supports standardized testing while minimizing patient discomfort during sample collection.

Sodium fluoride effectively slows down glycolysis, reducing glucose degradation during transport and storage. This helps laboratories obtain more reliable glucose and lactate measurements.
EDTA K2 ensures that blood remains unclotted, allowing for smooth processing and consistent analysis without interference from fibrin formation.
The pre-calibrated vacuum system guarantees a consistent 2 ml blood draw, maintaining the correct blood-to-additive ratio required for accurate test results.
Manufactured from transparent medical-grade PET, the tube provides excellent chemical stability, impact resistance, and clear visibility of the sample.
The gray rubber stopper and cap create a tight seal to prevent leakage and contamination during handling and transportation.
The 2ml Sodium Fluoride + EDTA K2 Blood Collection Tube is commonly used in diagnostic and clinical settings for tests where glucose stability is critical, including:
Blood glucose testing
Oral glucose tolerance test (OGTT)
Lactate measurement
Metabolic and endocrine screening
Diabetes monitoring and screening programs
These applications rely heavily on sample integrity during the pre-analytical phase, making tube quality and additive accuracy essential.
Laboratories sourcing glucose collection tubes should prioritize consistent additive formulation and vacuum performance. You can explore qualified supply options and documentation support at EDTA TUBE.
Verify patient identity and prepare the venipuncture site according to standard procedures.
Inspect the tube to ensure it is within its expiration date and free from damage.
Perform venipuncture and allow the tube to fill automatically to the 2 ml mark via vacuum.
Gently invert the tube 8–10 times immediately after collection to mix blood with additives.
Transport and process the sample according to laboratory protocols to ensure optimal accuracy.
Proper mixing and timely handling are essential to maximize the effectiveness of sodium fluoride and EDTA K2.
For tubes containing chemical additives, manufacturing precision directly affects test accuracy. Variations in sodium fluoride or EDTA K2 dosage, inconsistent vacuum levels, or substandard materials may compromise glucose stability and lead to unreliable results.
A trusted supplier ensures:
Accurate additive dosing
Consistent vacuum calibration
Batch traceability and quality control
Compliance with international medical consumables standards
Working with an experienced manufacturer helps laboratories and distributors maintain consistent testing performance. For detailed specifications, samples, or bulk purchasing discussions, EDTA TUBE provides technical support and sourcing assistance.
Draw Volume: 2 ml
Additives: Sodium Fluoride + EDTA K2
Tube Material: Medical-grade PET
Tube Size: 13 × 75 mm
Cap Color: Gray
Sterilization: EO or gamma sterilized
Intended Use: Glucose and metabolic testing
Shelf Life: Labeled per batch
EDTA tube is a type of blood collection tube that contains ethylenediaminetetraacetic acid (EDTA) as an anticoagulant. EDTA works by binding to calcium ions in the blood, which prevents clotting and helps preserve the sample for laboratory analysis.
The primary purpose of using EDTA tubes is to collect blood samples for various laboratory tests, particularly those related to blood cell counts and blood typing. EDTA helps maintain the integrity of the blood sample by preventing coagulation and ensuring reliable test results.
EDTA works by chelating calcium ions in the blood, which are essential for the coagulation process. By binding these ions, EDTA prevents clot formation.
Sinymedical offers K2 and K3 EDTA tubes, which differ in the number of potassium ions they contain, catering to various laboratory needs.
K2 EDTA tubes contain dipotassium EDTA, while K3 EDTA tubes contain tripotassium EDTA, differing in concentration and specific applications.
Both types effectively prevent clotting, but the choice between them may depend on specific laboratory protocols and test requirements.
Yes, K2 EDTA tubes are suitable for most hematological tests, including complete blood counts (CBC) and blood typing.
K3 EDTA tubes are often used in specialized applications where a higher concentration of potassium is needed, such as certain molecular assays.
Store EDTA tubes at room temperature (4-25°C) and avoid exposure to extreme temperatures or direct sunlight to maintain their effectiveness. It is important to check the expiration date on the tubes and avoid using expired products
EDTA tubes can be purchased from various medical supply companies, laboratory equipment suppliers, and online retailers for high-quality EDTA tubes.
You can visit our website at [https://www.edtatube.com/]https://www.sinymedical.com/edta-tube/).
No, EDTA tubes are designed for single use only to ensure safety and prevent contamination.
Yes, our EDTA tubes meet international quality standards and undergo rigorous testing to ensure reliability and safety.
Our EDTA tubes are made from high-quality polyethylene or glass materials that ensure durability and clarity for accurate readings.
Our capacity can be 500,000PCS per day.
Yes, we offer customization options for branding and labeling based on your specific requirements.
Yes, Sinymedical has a dedicated customer support team. You can reach them through the contact information provided on their website.
Yes, Sinymedical offers international shipping to many countries. Please check our shipping policy for more details or contact customer support for specific inquiries.
