Siny Factory EDTA-K2 Blood Collection Tube

Product NameEDTA Tubes
Tube MaterialPET/Glass
OEM/ODMYes
CertificateCE, ISO13485, ISO9001
UsageBlood Collection
SterileIrradiation Sterilization
SampleFree
ServiceThe groups we serve: are distributors, import traders, government procurement, Buying Agents, and medical chain stores. We provide one-stop procurement for you to simplify your procurement process
Category

Product Overview

The Siny Factory EDTA-K2 Blood Collection Tube is a sterile, single-use vacuum tube designed for accurate whole blood collection in clinical and laboratory environments. It contains a precisely dosed EDTA-K2 anticoagulant, which prevents blood coagulation by binding calcium ions while preserving cellular morphology.

Manufactured under controlled production conditions, this tube is intended for routine hematology testing where sample integrity and repeatability are critical. Its stable vacuum performance, uniform additive distribution, and medical-grade materials make it suitable for hospitals, diagnostic laboratories, and research institutions seeking consistent pre-analytical results.

Understanding EDTA-K2 in Blood Collection

EDTA-K2 (dipotassium ethylenediaminetetraacetate) is one of the most widely used anticoagulants in hematology. It effectively inhibits the coagulation cascade by chelating free calcium ions in the blood, ensuring that the sample remains fluid after collection.

Compared with other anticoagulants, EDTA-K2 is preferred for blood cell analysis because it helps maintain the natural size, shape, and distribution of red blood cells, white blood cells, and platelets. This makes EDTA-K2 tubes a standard choice for complete blood counts and related tests that rely on accurate cellular evaluation.

The Use of Different Vacuum EDTA Tubes

Volume/mlSize/mmAdditiveSeparatorMaterialCap ColorClosure
2ml13X75EDTA K2 / EDTA K3/PET/GLASSPurple Cap TubeSafety Cap+Rubber or Rubber Stopper
3ml13X75EDTA K2 / EDTA K3/
4ml13X75EDTA K2 / EDTA K3/
5ml13X75EDTA K2 / EDTA K3/
6ml13X100EDTA K2 / EDTA K3/
7ml13X100EDTA K2 / EDTA K3/
8ml16X100EDTA K2 / EDTA K3/
9ml16X100EDTA K2 / EDTA K3/
10ml16X100EDTA K2 / EDTA K3/
If You Need a Customized customized Blood collection tube, Please Contact Us

EDTA Tubes for Blood Collection

EDTA Blood Collection Tube

Key Features of Siny Factory EDTA-K2 Blood Collection Tube

Precise Anticoagulant Dosing

Each tube contains a carefully controlled amount of EDTA-K2, applied through a uniform coating process. This ensures immediate anticoagulation and maintains a consistent blood-to-additive ratio, which is essential for reliable laboratory results.

Stable Vacuum Performance

The tube is manufactured with a calibrated vacuum system that draws the intended blood volume accurately. Consistent fill volume reduces the risk of dilution errors and supports compatibility with automated hematology analyzers.

Medical-Grade Tube Materials

The tube body is produced using high-transparency medical-grade PET, offering good mechanical strength and clear visibility of the specimen. The stopper is designed to provide a secure seal, minimizing leakage and contamination risks during handling and transport.

Standardized Identification

A purple cap is used in accordance with international color-coding conventions for EDTA tubes, enabling quick identification during sample collection and laboratory processing.

Clinical Applications

The Siny Factory EDTA-K2 Blood Collection Tube is suitable for a wide range of diagnostic and research uses, including:

  • Complete Blood Count (CBC)

  • Hematocrit and hemoglobin analysis

  • Platelet count and morphology evaluation

  • White blood cell differential testing

  • Blood typing and immunohematology procedures

  • Whole blood sample preparation for molecular or cellular studies

These applications require stable anticoagulation and preserved cellular structure, which EDTA-K2 is specifically designed to support.

Recommended Usage Procedure

  1. Verify that the tube packaging is intact and within its shelf life.

  2. Perform venipuncture using standard blood collection techniques and compatible vacuum systems.

  3. Allow the tube to fill automatically to its nominal volume.

  4. Gently invert the tube 8–10 times immediately after collection to ensure complete mixing of blood and EDTA-K2.

  5. Transport and store the sample according to laboratory guidelines prior to analysis.

Proper handling helps maintain sample quality and reduces the risk of pre-analytical errors.

Request More Information

If you are sourcing Siny Factory EDTA-K2 Blood Collection Tubes for hospital use, laboratory distribution, or OEM projects, we welcome your inquiry.
Please contact us to discuss technical specifications, samples, customization options, and pricing. Our team is ready to support your blood collection needs with a stable supply and professional service.

EDTA tube is a type of blood collection tube that contains ethylenediaminetetraacetic acid (EDTA) as an anticoagulant. EDTA works by binding to calcium ions in the blood, which prevents clotting and helps preserve the sample for laboratory analysis.

Store EDTA tubes at room temperature (4-25°C) and avoid exposure to extreme temperatures or direct sunlight to maintain their effectiveness. It is important to check the expiration date on the tubes and avoid using expired products

Get a Free Quote