| Product Name | EDTA Tubes |
| Tube Material | PET/Glass |
| OEM/ODM | Yes |
| Certificate | CE, ISO13485, ISO9001 |
| Usage | Blood Collection |
| Sterile | Irradiation Sterilization |
| Sample | Free |
| Service | The groups we serve: are distributors, import traders, government procurement, Buying Agents, and medical chain stores. We provide one-stop procurement for you to simplify your procurement process |
The Siny Medical EDTA Disposable Blood Collection Tube is a sterile, single-use vacuum tube designed for collecting and preserving whole blood samples for hematological analysis. Pre-loaded with ethylenediaminetetraacetic acid (EDTA), this tube reliably prevents blood clotting by chelating calcium ions, ensuring that cellular components remain intact for accurate testing. Its consistent performance and ease of use make it a critical consumable in clinical laboratories, hospitals, and diagnostic centers.
EDTA blood collection tubes are widely accepted as the standard for complete blood counts (CBC), blood smears, white blood cell differentials, and other essential blood work. To support reliable laboratory workflows, selecting a reputable supplier and high-quality EDTA tubes is vital — you can explore validated options at edtatube and contact us for product information.
A Siny Medical EDTA Disposable Blood Collection Tube is an evacuated container that contains a controlled amount of EDTA in either spray-dried or liquid form. When blood enters the tube, the EDTA immediately binds calcium ions, which are essential for the clotting cascade, effectively preventing coagulation and preserving the sample in its whole blood state.
These tubes are color-coded (typically purple or lavender) to indicate the presence of the EDTA additive and are manufactured from medical-grade PET plastic or glass, providing durability, clarity for visual inspection, and compatibility with standard phlebotomy equipment and analyzers.
| Volume/ml | Size/mm | Additive | Separator | Material | Cap Color | Closure |
| 2ml | 13X75 | EDTA K2 / EDTA K3 | / | PET/GLASS | Purple Cap Tube | Safety Cap+Rubber or Rubber Stopper |
| 3ml | 13X75 | EDTA K2 / EDTA K3 | / | |||
| 4ml | 13X75 | EDTA K2 / EDTA K3 | / | |||
| 5ml | 13X75 | EDTA K2 / EDTA K3 | / | |||
| 6ml | 13X100 | EDTA K2 / EDTA K3 | / | |||
| 7ml | 13X100 | EDTA K2 / EDTA K3 | / | |||
| 8ml | 16X100 | EDTA K2 / EDTA K3 | / | |||
| 9ml | 16X100 | EDTA K2 / EDTA K3 | / | |||
| 10ml | 16X100 | EDTA K2 / EDTA K3 | / | |||
| If You Need a Customized customized Blood collection tube, Please Contact Us | ||||||


The Medical EDTA Disposable Blood Collection Tube is essential in a wide range of clinical and laboratory settings:
Complete Blood Count (CBC): Accurate measurement of red and white blood cells, hemoglobin, hematocrit, and platelets.
Blood Smear Preparation: Preserved sample quality enables detailed morphological analysis under microscopy.
Differential Leukocyte Count & Reticulocyte Count: Critical for diagnosing infections, anemia, and hematologic disorders.
Blood Typing and Crossmatching: Used in transfusion medicine and compatibility testing.
Molecular and Genetic Testing: EDTA-anticoagulated whole blood is useful in DNA/RNA extraction workflows due to preservation of nucleic acids.
Using the correct tube type for these procedures prevents sample rejection and ensures lab reliability. For procurement teams comparing EDTA tubes across suppliers, quality parameters such as additive consistency and material strength should drive decision-making — request technical details from edtatube to support your purchasing strategy.
A Medical EDTA Disposable Blood Collection Tube typically features:
Tube Material: Medical-grade PET or glass for strength and clarity
Additive: EDTA K2 or K3 anticoagulant
Color Coding: Lavender or purple cap for easy identification
Sterilization: EO or gamma sterilized prior to packaging
Vacuum Calibration: Pre-measured to ensure accurate blood draw volume
Batch Traceability: Clear labeling with lot number for quality assurance
These design elements ensure reliable performance in high-throughput laboratory workflows and compatibility with automated analyzers.
Prepare the Patient and Site: Follow standard venipuncture protocols for identification and site cleaning.
Inspect the Tube: Check expiration date and visual condition before use.
Collect Blood: Attach the tube to a vacuum holder and allow the pre-calibrated vacuum to draw the required volume of blood.
Mix the Sample: Immediately invert the tube gently 8–10 times to ensure thorough mixing of blood with the EDTA additive.
Label and Transport: Mark the tube clearly and transport it to the laboratory promptly under recommended conditions.
Proper sample handling and timely processing help maximize the anticoagulant effectiveness of EDTA and reduce risks of clot formation or hemolysis.
This product is an in vitro diagnostic medical device. Users must follow local regulations and institutional policies for clinical specimen collection and disposal. For documentation (MSDS, sterility and test reports), request the relevant lot documentation when placing an order.
EDTA tube is a type of blood collection tube that contains ethylenediaminetetraacetic acid (EDTA) as an anticoagulant. EDTA works by binding to calcium ions in the blood, which prevents clotting and helps preserve the sample for laboratory analysis.
The primary purpose of using EDTA tubes is to collect blood samples for various laboratory tests, particularly those related to blood cell counts and blood typing. EDTA helps maintain the integrity of the blood sample by preventing coagulation and ensuring reliable test results.
EDTA works by chelating calcium ions in the blood, which are essential for the coagulation process. By binding these ions, EDTA prevents clot formation.
Sinymedical offers K2 and K3 EDTA tubes, which differ in the number of potassium ions they contain, catering to various laboratory needs.
K2 EDTA tubes contain dipotassium EDTA, while K3 EDTA tubes contain tripotassium EDTA, differing in concentration and specific applications.
Both types effectively prevent clotting, but the choice between them may depend on specific laboratory protocols and test requirements.
Yes, K2 EDTA tubes are suitable for most hematological tests, including complete blood counts (CBC) and blood typing.
K3 EDTA tubes are often used in specialized applications where a higher concentration of potassium is needed, such as certain molecular assays.
Store EDTA tubes at room temperature (4-25°C) and avoid exposure to extreme temperatures or direct sunlight to maintain their effectiveness. It is important to check the expiration date on the tubes and avoid using expired products
EDTA tubes can be purchased from various medical supply companies, laboratory equipment suppliers, and online retailers for high-quality EDTA tubes.
You can visit our website at [https://www.edtatube.com/]https://www.sinymedical.com/edta-tube/).
No, EDTA tubes are designed for single use only to ensure safety and prevent contamination.
Yes, our EDTA tubes meet international quality standards and undergo rigorous testing to ensure reliability and safety.
Our EDTA tubes are made from high-quality polyethylene or glass materials that ensure durability and clarity for accurate readings.
Our capacity can be 500,000PCS per day.
Yes, we offer customization options for branding and labeling based on your specific requirements.
Yes, Sinymedical has a dedicated customer support team. You can reach them through the contact information provided on their website.
Yes, Sinymedical offers international shipping to many countries. Please check our shipping policy for more details or contact customer support for specific inquiries.
